6180 - p01221 - Processor right door and top cover open message

PROBLEM:

Fault code P01-221 red led's on two PWBA in LVPS Pos 3&4 with load and pos 2,3 &4 sometimes without Load

ACTIONS:

- Action #1: Follow RAP
- Resolve: Replaced PHN DIO #2

- Action #2: Loose wire p/J 254 wire 1a
- Resolve: Repaired

- Action #3: Checked OHMs wiring and switches
- Resolve: All okay

- Action #4: Swap LVPS
- Resolve: No change

- Action #5: Check all connectors in wiring path
- Resolve: Repaired bent pin wire 33 (green) in P/J 381 , reseated connector

RESOLVE:

Action #5 Resolved problem

Machine Specs: 6180, SVR-Full Refurb,-VLD BLue Belt


Technician: Jim Dorreman
Date: 8/15/2007